Main Propulsion Plant DD445 and 692 Classes and Converted

When the flow of steam is in excess of 5,000 pounds per hour in (B & W) boilers or 5,600 pounds per hour in (F. W.) boilers, or 2.0" of water pressure differential, the instruction sign on the Bailey superheater protection device "Secure Burners" will not be illuminated, while the pointer on the Yarnall-Waring instrument will be in the green zone.

Learn More

Steam Capacity Conversion Table | Industrial Controls

26 rows · Dec 13, 2010 · Heating Water with Steam Example: How many lbs per hour of steam is need to heat 40

Learn More

Steaming Rate - Industrial Steam Boilers Manufacturers

However, if a steaming rate is used to specify boiler size then the steaming rate must be qualified—"from and at 212°F"; gross or net; pounds or kilograms per hour. Clayton Steam Generators are available in many sizes and as portable steam boilers. Many are available as medium pressure steam boilers and high pressure steam boilers for sale.

Learn More

2. BOILERS - Bureau of Energy Efficiency

orated to steam per hour. Maximum continuous rating is the hourly evaporation that can be maintained for 24 hours. F & A means the amount of steam generated from water at 100 °C to saturated steam at 100 °C. Indian Boiler Regulation The Indian Boilers Act was enacted to consolidate and amend the law relating to steam boilers.

Learn More

Boiler Capacity - Engineering ToolBox

the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 oF, with feedwater at 0 Psig and 212 oF. A BHP is equivalent to 33,475 BTU/Hr or 8430 Kcal/Hr and it should be noted that a boiler horsepower is 13.1547 times a normal horsepower.

Learn More

Boiler Horsepower to Btus Per Hour | Kyle's Converter

6 Boiler Horsepower to Btus Per Hour = 200852.1553: 300 Boiler Horsepower to Btus Per Hour = 10042607.764: 7 Boiler Horsepower to Btus Per Hour = 234327.5145: 400 Boiler Horsepower to Btus Per Hour = 13390143.6853: 8 Boiler Horsepower to Btus Per Hour = 267802.8737: 500 Boiler Horsepower to Btus Per Hour = 16737679.6066: 9 Boiler Horsepower to

Learn More

Calculate How To

In the following equations, the operating cost of the boiler is CO per hour and the process requires S pounds/hour (lb/h) of steam. To deliver this much steam, it is necessary to actually generate (1+X)S lb/h of steam, where X is a factor typically ranging from 5 to 20%. So we already have two distinct equations to determine the cost of steam

Learn More

Calculating the Cost of Steam | Thermaxx Jackets

Jan 31, 2013 · Hg = enthalpy of steam, in Btu/lb. hf = enthalpy of boiler feedwater in Btu/lb. ηB = true boiler efficiency (per ASME PTC 4.1 method) 1,000 = cost measured in units of 1,000 lbs. per hour. In this simplified calculation method, the formula assumes that one boiler is being used, one fuel and a single steam pressure. True Boiler Efficiency (ηB)

Learn More

Methods of Estimating Steam Consumption | Spirax Sarco

The mean steam consumption of a flow type application like a process heat exchanger or heating calorifier can be determined from Equation 2.6.6, as shown in Equation 2.6.7. But as the mean heat transfer is, itself, calculated from the mass flow, the specific heat, and the temperature rise, it is easier to use Equation 2.6.7.

Learn More

Boiler Ratings and Boiler Load - Alken-Murray

Boiler Ratings and Boiler Load . The oldest method of rating boilers, still used to rate small boilers, is by horsepower (hp). One horsepower is defined as the ability to evaporate 34.5 lbs of water into steam at 212 deg. F and above. Large boiler capacity is generally given in lbs of steam evaporated per hour, under specified steam conditions.

Learn More

Steaming Rate - Industrial Steam Boilers Manufacturers

Boiler Feed Water Flow Rate Requirements Chart | Nalco PTS

Learn More

Steam Calculators: Boiler Calculator

Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.

Learn More

Pipe Sizing Steam Supply andCondensateReturn Lines

steam main to the new unit. The use of the tables is best described by solving a typical problem: Assume a boiler operates at a steam pressure of 15 psig and is supplying a 300-ton steam absorption machine which requires a minimum operating pressure of 12 psig. There is a 2 psig pressure drop along the steam …

Learn More

Use Feedwater Economizers for Waste Heat Recovery

An 80% efficient boiler generates 45,000 pounds per hour (lb/hr) of 150-pounds-per-square-inch-gauge (psig) steam by burning natural gas. Condensate is returned to the boiler and mixed with makeup water to yield 117°F feedwater. The stack temperature is measured at 500°F. Determine the

Learn More

Boiler Formulas - Debco Equipment

Boiler Formulas: Common Conversion Factors. Boiler HP x 34.5 Boiler HP x.069 Boiler HP x 33.4 Boiler HP x 139 BTU/Hour Output ч 240 EDR/1000 x 0.5 Lbs of Steam /Hr ч 500 = Lbs. of Steam per Hour = Evaporation Rate Gallons per Minute (GPM) = MBTU per Hour Output (MBH) = Sq. Feet of Equivalent Direct Radiation (EDR) = Sq. Feet of Equivalent

Learn More

Steam Tables… - Missouri

steam table. Total Heat of Steam (Column 6). The sum of the Heat of the Liquid (Column 4) and Latent Heat (Column 5) in Btu. It is the total heat in steam above 32°F. Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound. Specific Volume of Steam (Column 8). The volume per unit of mass in cubic feet per pound.

Learn More

Used Watertube Boilers - Cleaver Brooks Boiler for Sale

We supply mobile boilers of up to 85,000 lbs/hr with both saturated and superheated steam capability. We also stock larger skid mounted boilers with superheated steam capacities of up to 300,000 lbs/hr.

Learn More